Search  

Floors, Interior - Tile or Stone

Concrete Subfloor

Areas of Application
  • over any structurally sound and even concrete subfloor
  • young concrete (concrete cured less than 28 days)
  • on or below grade concrete subject to moisture migration
  • post-tensioned or pre-stressed concrete

Limitations

  • minimum 2" x 2" (50 mm x 50 mm) tile
  • concrete slabs subject to moisture migration must have all seams in Schluter-DITRA matting sealed with Schluter-KERDI-BAND using unmodified thin-set mortar

 

Legend

*** Essential
**   Significant
*     Helpful


Requirements
  • slab to be structurally sound
  • slab to be free of waxy or oily films and curing compounds (when present, mechanical scarifying is necessary)
  • the installation of Schluter-DITRA and tile can begin as soon as the slab can be walked upon

Substrate Preparation

  • any leveling or sloping of the slab or assembly must be done prior to installing Schluter-DITRA

Movement Joints

Setting and Grouting Materials

  • unmodified thin-set mortar - ANSI A118.1
  • grout - ANSI A118.3, A118.6, A118.7, A118.8

Setting and Grouting Specifications

  • tile - ANSI A108.5
  • grout - ANSI A108.6, A108.9, A108.10

Other Considerations

  • where a waterproof floor is required, all Schluter-DITRA seams and floor/wall transitions must be sealed with Schluter-KERDI-BAND using unmodified thin-set mortar; see waterproofing requirements for more details
  • certain moisture-sensitive stones, e.g., green marble, or resin-backed tiles may require special setting materials. Consult stone supplier and Schluter-Systems for more information.

 


open/close   Further information
open/close   Download DITRA Installation Handbook
open/close   Download Ditra Installation Information