Floors, Interior - Tile or Stone
Concrete SubfloorAreas of Application
Limitations
|
|
Legend
*** Essential
** Significant
* Helpful
Requirements
*** Essential
** Significant
* Helpful
Requirements
- slab to be structurally sound
- slab to be free of waxy or oily films and curing compounds (when present, mechanical scarifying is necessary)
- the installation of Schluter-DITRA and tile can begin as soon as the slab can be walked upon
Substrate Preparation
- any leveling or sloping of the slab or assembly must be done prior to installing Schluter-DITRA
Movement Joints
- Schluter-DITRA does not eliminate the need for movement joints, including perimeter joints, within the tiled surface. Movement joints should be installed in accordance with industry standards and norms; see guidelines for the placement of movement joints for more details
Setting and Grouting Materials
- unmodified thin-set mortar - ANSI A118.1
- grout - ANSI A118.3, A118.6, A118.7, A118.8
Setting and Grouting Specifications
- tile - ANSI A108.5
- grout - ANSI A108.6, A108.9, A108.10
Other Considerations
- where a waterproof floor is required, all Schluter-DITRA seams and floor/wall transitions must be sealed with Schluter-KERDI-BAND using unmodified thin-set mortar; see waterproofing requirements for more details
- certain moisture-sensitive stones, e.g., green marble, or resin-backed tiles may require special setting materials. Consult stone supplier and Schluter-Systems for more information.

Further information