Heated Floors, Interior - Tile or Stone

Concrete Substrate - Structural Concrete Slab

Areas of Application
  • over structurally sound radiant-heated concrete floors

Limitations

  • minimum 2" x 2" (50 mm x 50 mm) tile
  • concrete slabs subject to moisture migration must have all seams in Schluter-DITRA and Schluter-DITRA-XL sealed with Schluter-KERDI-BAND using unmodified thin-set mortar

 

 

    Legend

    *** Essential
    **   Significant
    *     Helpful


    Requirements
    • slab to be structurally sound
    • slab to be free of waxy or oily films and curing compounds (when present, mechanical scarifying is necessary)
    • the installation of Schluter-DITRA or Schluter-DITRA-XL and tile can begin as soon as the slab can be walked upon

    Substrate Preparation

    • any leveling or sloping of the slab or assembly must be done prior to installing Schluter-DITRA and Schluter-DITRA-XL

    Movement Joints

    Setting and Grouting Materials

    • unmodified thin-set mortar – ANSI A118.1
    • grout – ANSI A118.3, A118.6, A118.7, A118.8

    Setting and Grouting Specifications

    • tile - ANSI A108.5
    • grout – ANSI A108.6, A108.9, A108.10

    Other Considerations

    • where a waterproof floor is required, all Schluter-DITRA and Schluter-DITRA-XL seams and floor/wall transitions must be sealed with Schluter-KERDI-BAND using unmodified thin-set mortar; see waterproofing requirements for more details
    • certain moisture-sensitive stones, e.g., green marble, or resin-backed tiles may require special setting materials. Consult stone supplier and Schluter-Systems for more information