Exterior Applications - Concrete Floors, Patios and Walkways

Areas of Application
  • exterior concrete where positive drainage below slab is provided
  • young concrete (concrete cured less than 28 days)
  • post-tensioned or pre-stressed concrete

Limitations

  • minimum 2" x 2" (50 mm x 50 mm) tile
  • for applications over occupied space, follow this link. Garages, open-air balconies with finished ceilings underneath, etc. should be treated as occupied space. Please contact us with any questions.

 

Legend

*** Essential
**   Significant
*     Helpful

Requirements

  • slab to be structurally sound
  • slab/assembly must be sloped for complete surface drainage
  • gravel bed or other means of drainage must be provided below slab
  • slab to be free of waxy or oily films and curing compounds (when present, mechanical scarifying is necessary)
  • all seams in Schluter-DITRA matting and floor/wall transitions must be sealed with Schluter-KERDI-BAND using unmodified thin-set mortar; see waterproofing requirements for more details

Substrate Preparation

  • sloping of the slab or assembly must be done prior to installing Schluter-DITRA

Movement Joints

Setting and Grouting Materials

  • unmodified thin-set mortar - ANSI A118.1
  • grout - A118.6, A118.7

Setting and Grouting Specifications

  • tile - ANSI A108.5
  • grout - A108.10