Schluter®-LIPROTEC-ECX es una fuente de alimentación LED y un regulador de intensidad en la pared, en un único dispositivo. Ofrece una regulación suave y uniforme con un rango de regulación del 5% al 100%. LIPROTEC-ECX puede controlar varios nichos KERDI-BOARD-SNLT (de hasta 60 vatios). Además, incluye tres placas frontales intercambiables para combinar con la mayoría de las decoraciones.
LIPROTEC-ECX no requiere ningún mantenimiento especial.
¿Está listo para instalar su regulador de intensidad Schluter®-LIPROTEC-ECX? Consulte paso a paso las instrucciones de instalación o vea nuestro completo vídeo de instalación a continuación.
Do we need to use all three LIPROTEC components? Can I use another driver, LED, or wire?
The LIPROTEC system is specifically designed to work together and is UL listed as a system. The cable and gland seal the wire outlet hole. The LED connectors are...
Leer másWhy is my LIPROTEC LED flashing?
The driver is overloaded or overheated. Check the sum of wattage on the driver and make sure it is below the rated output (LIPROTEC-ECX: 60W or...
Leer másWhat are the benefits of the LIPROTEC-ECX driver vs the LIPROTEC-ECD?
LIPROTEC-ECX is an all-in-one solution with one connection point to run from the junction box directly to the LED.
Leer másCan I run more than one LED to the LIPROTEC-ECX driver?
Yes. The LED light is 1.7 watts and the LIPROTEC-ECX control is rated up to 60 watts. This means that you can run up to 30 niches on the LIPROTEC-ECD...
Leer másCan the LIPROTEC-ECX integrate with my smart home?
Do I need special wiring for the LIPROTEC-ECX?
No, but the LIPROTEC-ECX needs to have the rough in wiring for high voltage (120V AC) on a particular end (the bottom) of the junction box, otherwise...
Leer másDoes the LIPROTEC-ECX need to be on its own circuit?
No, the LIPROTEC system can be jumped off an existing lighting circuit if needed. Contact your local electrician for guidance and code compliance.
Leer másCan the LIPROTEC-ECX be installed in a double gang box, along side an existing switch?
Yes, but a voltage barrier or divider (not included) needs to be installed between the two switches. Contact your local electrician for guidance and...
Leer másCan I pull power from my DITRA-HEAT or other floor heating circuit to power my LIPROTEC LED?
No. Floor heating should be on a dedicated circuit. You also increase the risk of accidentally miswiring the lighting into a 240V circuit.
Leer másDoes the LIPROTEC-ECX need to be on a GFCI circuit?
No. GFCIs are typically not used on a light circuit but this will not affect the performance of the LIPROTEC system.
Leer másCan I connect the LIPROTEC-ECX to 240V power?
No. This will damage the driver and void the warranty. The driver is rated for single-phase 110VAC-120VAC power.
Leer másWhat would happen to the LIPROTEC system in case of a power surge or brownout?
Both Schluter drivers have built-in protection against power fluctuations and will shut down in either of the situations listed above.
Leer másWhat if my LIPROTEC LED turns on but doesn't dim?
The slider is misaligned. Remove the faceplate on the ECX. Slide the black dimming lever on the ECX housing to the bottom and the face plate slider to...
Leer másI have verified a 120V input to my power supply and 24V output but my LIPROTEC LED still does not illuminate. What should I do?
Ensure that the low voltage (+ and -) connections are correct and not reversed. The connections should be...
Leer más