Calcule sin esfuerzo sus necesidades de membranas y cables.
El módulo de potencia puede utilizarse junto con los termostatos DITRA-HEAT-E-RT o DITRA-HEAT-E-R cuando la carga de calefacción supere los 15 amperios (por ejemplo, en grandes superficies de piso) para mantener un único punto de control. Se pueden conectar hasta 16 módulos de potencia DITRA-HEAT-E-RR en serie mediante un cable de señal de baja tensión a un solo termostato DITRA-HEAT-E-RT o DITRA-HEAT-E-R.
Please refer to the Quick guide and Schluter®-DITRA-HEAT Installation Handbook for complete DITRA-HEAT system installation instructions.
1. The power supply must be shut off and all electrical connections must be made by a qualified person, according to the electrical and building codes effective in your region.
2. Connect the heating cable ground braid to the ground wire from the electrical panel.
3. Remove the faceplate from the module power base by loosening the screw and tilting the module upward. Remove the back cover clip as well.
4. For ease of installation, form the electrical line wires into an “M” or accordion shape. This will make it easier to fold them neatly into the electrical box. Loosen the load screws at the top of the module until they stop.
5. Insert the heating cable conductors into the load terminals from the bottom. Since there is no polarity, either heating cable conductor can be connected to either load terminal.
6. Secure the conductors by tightening the screws.
7. Insert the electrical line wires into the line terminals from the top. Refer to the back of module for proper wiring configuration.
8. Secure the wires by tightening the screws and fold the wires into the electrical box. Align and secure the module power base to the electrical box.
9. To install signal wire, connect a 2 conductor 20 AWG wire from terminal A on the thermostat to terminal C on the power module and from terminal B on thermostat to terminal D on power module. Note: Wiring orientation is required for power module to operate correctly.
10. Secure the conductors by tightening the screws.
11. The power, heating cable, and signal connections are now complete. Replace the power module faceplate and tighten the screw at the bottom of the unit.
Note: Up to 16 DITRA-HEAT-E-RR power modules may be connected in series to a single DITRA-HEAT-E-WIFI, DITRA-HEAT-E-RT, or DITRA-HEAT-E-R thermostat.
How do I connect an expansion unit/power module to the DITRA-HEAT-E-WIFI, DITRA-HEAT-E-RT or DITRA-HEAT-E-R thermostats?
Connect a 2 conductor 20 AWG wire from terminal A on the thermostat to terminal C on the power module and from...
Leer másc-UL-us according to the following standards:
UL E-file: E157297
GFCI: UL 943
CSA C22.2, No. 144. 1-06
Schluter®-DITRA-HEAT: System Components