Search Results for

Movement Joint Profiles / Mortar Bed Joint Profiles

Schluter®-DILEX-MP/-MPV
Schluter®-DILEX-MP/-MPV Schluter®-DILEX-MP/-MPV

Movement Joint Profiles / Mortar Bed Joint Profiles

Schluter®-DILEX-MP/-MPV
Schluter®-DILEX-MP is a screed joint profile with rigid PVC side sections that protect tile edges and a soft chlorinated polyethylene (CPE) movement zone that separates individual fields in the tile assembly and forms the visible surface.
View Product Details

Profiles

Schluter®-KERDI-BOARD-ZB
Schluter®-KERDI-BOARD-ZB Schluter®-KERDI-BOARD-ZB

Profiles

Schluter®-KERDI-BOARD-ZB
The Schluter®-KERDI-BOARD-ZB is a U-shaped stainless steel profile with three perforated sides for the tiling and reinforcement of open-ended partition walls.
View Product Details

Profiles

Schluter®-KERDI-BOARD-ZC
Schluter®-KERDI-BOARD-ZC Schluter®-KERDI-BOARD-ZC

Profiles

Schluter®-KERDI-BOARD-ZC
Schluter®-KERDI-BOARD-ZC is a U-shaped brushed stainless steel profile with a perforated topside, and a smooth underside with anchoring leg for finishing countertops, vanities, or similar structures made with KERDI-BOARD.
View Product Details

For Stairs / Cover the Sub-Assembly

Schluter®-TREP-TAP
Schluter®-TREP-TAP Schluter®-TREP-TAP

For Stairs / Cover the Sub-Assembly

Schluter®-TREP-TAP
The Schluter®-TREP-TAP is an anodized aluminum cover profile that integrates with the TREP-S and TREP-B stair-nosing profiles to conceal the top of the riser.
View Product Details
Dan Marvin Joins Schluter-Systems

Schluter-Systems is pleased to announce the appointment of Dan Marvin to the position of Director of Product Standards and Sustainability.

Project Design

Education for Architects and Designers

Find out more about AIA and IDCEC continuing education seminars available.

New Dallas-Fort Worth Facility

Schluter Systems Opens Additional Distribution, Office, and Training Center in Dallas-Fort Worth New Building is over 500,000 sq. ft.

  • 1(current)
  • 2
  • 3
Q:

Why are two floor temperature sensors provided with the Schluter®-DITRA-HEAT system?

A:

Both floor temperature sensors are installed within the tile assembly. One sensor is connected to the thermostat, while...

Read more
Q:

What is the length of the sensor wire and can it be extended?

A:

The floor temperature sensor is appx. 13 ft (4 m) in length and can be extended using an 18 AWG, 2-wire cable...

Read more
Q:

How do I protect my laminate / LVT / SPC flooring or similar for a maximum floor temperature of 82°F (28°C)?

A:

In the "Advanced" settings, when in "Floor" control mode or in "Ambient" control mode, set "Max. Floor Temperature" to...

Read more
  • 1(current)
  • 2
  • 3

Data sheets 2  Results

Floor Drains Data Sheet.pdf
1.51 MB
PDF
Floor Profiles Data Sheet.pdf
1.14 MB
PDF

Product Table 2  Results

Floor_Warming.pdf
3.79 MB
PDF
FloorDrains.pdf
4.37 MB
PDF
  • 1(current)
  • 2
  • 3
09:44

Schluter®--KERDI-LINE & heated floor

02:06

Schluter®-Systems: Anatomy of a Tiled Floor

03:41

Schluter®-Systems: Benefits of a Tiled Floor

08:27

How to install DITRA-HEAT electric floor warming in a shower

  • 1(current)
  • 2
  • 3